Roof, property and home type

Can my roof support solar panels? The weight per square foot, worked out

Divide a current 430 watt panel's 46.3 pounds by its 21 square feet and you get 2.2 pounds per square foot; add the rails and roof feet in the Department of Energy's residential cost model and the array comes to about 2.9 pounds per square foot. Washington accepts a roof without engineering up to 4 pounds per square foot of total solar dead load, with conditions.

Snow is the bigger number on most roofs. Washington's no-engineering route ends where the ground snow load passes 70 pounds per square foot, and Oregon's prescriptive checklist lets attachments into the framing sit more than 24 inches apart only where the ground snow load is 36 pounds per square foot or less. On a roof designed for real snow the array is the smaller of the two loads, so the structural check is mostly about where its weight lands: how many rafters share it, how far apart the roof feet sit, and what happens when snow piles onto glass that used to be shingle.

Three building authorities, read side by side, give three different answers to the practical question of when an installer may skip the structural engineer. Washington writes a five-part test into its state amendment. Oregon publishes a prescriptive checklist that also asks about rafter spacing, roofing layers and attachment spacing. Charleston County, South Carolina, prints the load cases on its permit form and has the applicant sign that a licensed engineer reviewed the structure, on every job. Where your house sits on that spectrum decides whether the roof question costs you a site visit or a stamped letter.

Panel weight divided by panel area: three current modules

Every distributed-load figure in a solar permit starts with one division: the module's weight over the area it covers. Manufacturers print both numbers on the datasheet, so a homeowner can redo the arithmetic for the exact panel on a quote. We ran it for two residential modules sold in 2026 and for the composite module the Department of Energy's national laboratory uses in its 2025 residential cost benchmark.

The Silfab SIL-430 QD datasheet (revision dated August 4, 2026) lists 21 kilograms (46.3 pounds) and a frame of 1,721 by 1,133 millimeters. That is 1.950 square meters, or 20.99 square feet, so the panel weighs 10.77 kilograms per square meter, which converts to 2.21 pounds per square foot. The pound route gives the same answer: 46.3 divided by 20.99 is 2.21.

The Qcells Q.TRON BLK M-G2+ product page gives 46.7 pounds and a format of 67.8 by 44.6 inches for the series, which covers 415 to 440 watt versions. Multiply the two sides and divide by 144 and the panel covers 21.00 square feet, so its own weight is 2.22 pounds per square foot. The National Laboratory of the Rockies (formerly NREL) benchmark model, which sits behind the DOE Q1 2025 cost benchmarks, describes a 1.9 by 1.03 meter composite module at 10.99 kilograms per square meter of module, or 2.25 pounds per square foot.

Module weight per square foot, computed from manufacturer and DOE model figures (checked October 31, 2026)
ModuleWeightSizeAreaOwn weight per sq ft
Silfab SIL-430 QD21 kg (46.3 lb)1,721 x 1,133 mm1.950 m2 (20.99 sq ft)10.77 kg/m2 = 2.21 psf
Qcells Q.TRON BLK M-G2+ (415 to 440 W series)46.7 lb (21.2 kg)67.8 x 44.6 in21.00 sq ft (1.951 m2)2.22 psf (10.86 kg/m2)
DOE 2025 residential model composite (about 400 W)10.99 kg per m2 of module1.9 x 1.03 m1.957 m2 (21.06 sq ft)2.25 psf

Three panels from three sources land within 0.04 pounds per square foot of each other. That convergence is the useful fact: modern residential modules of about 21 square feet with aluminum frames and 3.2 millimeter glass, which is what the Silfab sheet specifies, weigh close to 2.2 pounds per square foot no matter whose name is on the label. A quote that uses a markedly heavier or lighter module should show its own datasheet, and the division takes a minute.

The conversion factor is worth having for any metric datasheet: one kilogram per square meter equals 0.2048 pounds per square foot, because a kilogram is 2.2046 pounds and a square meter is 10.764 square feet. Washington's own amendment prints its 4 pound threshold as 19.5 kilograms per square meter, and 4 times 4.882 confirms it.

What rails, roof feet and wiring add to the panel figure

Panels never sit on a roof by themselves. A typical pitched-roof residential system bolts aluminum rails to flashed feet screwed into rafters or trusses, clamps the modules to the rails, and runs wiring and electronics under the glass. Washington's threshold explicitly counts the lot: modules, supports, mountings, raceways and all other appurtenances.

The DOE 2025 cost benchmark model files carry weights for each layer because the model prices shipping by the kilogram. For the 8 kW residential case, built from twenty 400 watt modules, the structural balance of system (roof mounts, rails and clamps) weighs 3.23 kilograms per square meter of module, or 0.66 pounds per square foot. Electrical balance of system weighs 8.4 kilograms per kilowatt of inverter capacity and the microinverters 3.6 kilograms per kilowatt, at an inverter load ratio of 1.14.

Spreading those electrical weights over the model's 39.2 square meters of modules adds 1.50 and 0.64 kilograms per square meter, or 0.31 and 0.13 pounds per square foot. Part of the electrical weight in that model, such as the combiner and breaker boxes, hangs on a wall rather than the roof, so treat the electrical line as a ceiling rather than a measurement.

Stacked dead load of the DOE 8 kW residential benchmark array, per square foot of module (2025 model weights)
LayerModel weightPer sq ftRunning total
Module10.99 kg/m22.25 psf2.25 psf
Roof mounts, rails, clamps3.23 kg/m20.66 psf2.91 psf
Electrical balance of system (upper bound, some is wall-mounted)8.4 kg per kW AC, spread over 39.2 m20.31 psf3.22 psf
Microinverters3.6 kg per kW AC, spread over 39.2 m20.13 psf3.35 psf

The module and racking line, 2.91 pounds per square foot, is the honest central figure for a flush-mounted array. The 3.35 at the bottom of the table is a deliberately generous upper bound that puts every electrical kilogram on the roof. Both clear Washington's 4 pound test and Oregon's 4.5 pound test with room to spare. The whole 8 kW array weighs about 1,229 pounds on the module and racking basis, spread over 422 square feet.

Heavier roofing does not change these numbers, because the threshold counts the solar system, not the roof covering it sits on. It does change what the framing already carries before the first panel goes up, which is why tile roofs get their own mounting rules and why reviewers ask what the existing covering is.

The load cases a reviewer runs, as Charleston County prints them

The structural rules for rooftop solar sit in the solar section of the residential code that a state or county adopts, numbered R324 in the editions read here. Washington's adopted text opens the rooftop part with the base sentence: rooftop-mounted photovoltaic panel systems installed on or above the roof covering shall be designed and installed in accordance with Section R907. The load cases themselves are printed on Charleston County, South Carolina, residential solar permit form, which reproduces sections R324.4.1.1 and R324.4.1.2 for applicants.

As that form prints them, the portions of the roof not covered by panels are designed for the ordinary dead loads and roof loads of the code. The portions covered by panels are checked twice. Case one is dead load including the panels plus snow load from the code's climatic design table. Case two is dead load without the panels plus roof live load or snow load, whichever is greater.

The two cases capture a real physical trade. Roof live load is the allowance for people, tools and materials on the roof during maintenance or reroofing. Nobody stands on the shingles under a panel, so the panel weight and the live load are not checked together under the panel; the reviewer checks the heavier of the two outcomes. Snow is different: it lands on the glass, so case one adds the panel weight and the snow at the same time.

The wind section on the same form says the rooftop panel systems and their supports must resist the component and cladding loads in the code's wind table, adjusted for height and exposure. Wind pulls up on an array as well as pushing down, so the uplift capacity of each roof foot, and the screw into the rafter beneath it, is part of the same structural question even though it does not show up in any pounds per square foot figure.

Reading the cases this way explains why a 3 pound array rarely decides the answer on its own. Under case two the array weight drops out altogether. Under case one it rides on top of the snow load, and on a roof designed for real snow the snow is the larger term by a wide margin.

Washington and Oregon: when the installer can skip the engineer

Washington amends the rooftop section with an exception, in WAC 51-51-03240 (effective March 16, 2024, and unchanged on the official page on October 31, 2026). The roof structure is deemed adequate to support the load of the rooftop system when all five conditions hold: the system is designed for the local wind speed and installed to the manufacturer's specifications; the ground snow load does not exceed 70 pounds per square foot; the total dead load of modules, supports, mountings, raceways and other appurtenances is no more than 4 pounds per square foot; the modules sit no more than 18 inches above the roofing surface; and the supports spread the load across enough framing members that no point load exceeds 50 pounds.

Oregon reaches a similar place through a form. The Building Codes Division's prescriptive rooftop solar checklist, form 440-5952 (5/24), posted by the City of Happy Valley, lists structural criteria under the Oregon Residential Specialty Code. A single No sends the project off the prescriptive path, as does a supporting structure that is a manufactured dwelling.

No-engineering structural tests compared (Washington WAC 51-51-03240 and Oregon form 440-5952, read October 31, 2026)
TestWashington exceptionOregon prescriptive checklist
Total solar dead load4 psf or less, including raceways and appurtenances4.5 psf or less, modules and racking
Ground snow load70 psf or less70 psf or less; 36 psf or less for framing attachments spaced more than 24 in
Height above roof18 in or less18 in or less, top of module to roof surface
Point loadNo point load over 50 lbNot stated as a weight; set by attachment spacing
FramingNot stated beyond spreading the load across framing membersConventional light frame; trusses or rafters at 24 in on center or less
RoofingNot statedMetal, single-layer wood shingles or shakes, or no more than two layers of composition shingle
WindDesigned for local wind speedExposure B or C; for wider roof-foot spacing, basic wind speed 120 mph or less in B, 110 mph or less in C
Manufactured homesNot statedExcluded from the prescriptive path

Oregon's form gives two attachment methods. The first fixes the rails straight into roof framing or blocking, with feet no more than 24 inches apart in any direction, or up to 48 inches where the ground snow load is 36 pounds per square foot or less, no foot lies within 3 feet of an edge, hip, eave or ridge, and the basic wind speed stays within the limits in the table. The second clamps to standing seam metal roofing: clamps with at least 115 pounds of allowable uplift capacity at spacing of 48 inches or more, or 75 pounds below that, spaced 24 to 60 inches along a seam, on 26 gauge or heavier steel panels no wider than 18 inches, screwed at 24 inches over half-inch structural sheathing.

The roofing line matters to anyone carrying old shingles. A house with three layers of composition shingle fails Oregon's checklist on that line alone, which is one more reason the question of replacing the roof before solar often answers itself. Metal roofs get their own path because a clamp on a seam avoids penetrations altogether; the metal roof page covers that mounting style, and the shingle roof page the flashed-foot style most homes use.

Oregon's form also sends rafter roofs to the rafter compliance conditions in the specialty code's own exception, items 1.4 through 1.6, which are not reproduced here. Trusses at 24 inches or closer pass the framing line directly. For manufactured homes, which the Oregon form excludes outright, see the separate guide on solar panels on a manufactured home.

Point loads: the 50 pound rule and attachment spacing

Total weight per square foot is an average. Rafters feel the array as a set of concentrated loads, one at each roof foot, and that is why Washington adds a point-load cap to its distributed-load cap. The two tests can disagree: an array well under 4 pounds per square foot can still put more than 50 pounds on a single foot if the feet are far apart.

The arithmetic is short. In portrait orientation with two rails per row, each rail carries half the module's 67.8 inch depth, or about 2.82 feet. A roof foot therefore supports a strip 2.82 feet deep by the spacing between feet. Multiply that tributary area by the array's weight per square foot and you have the dead load on that foot.

Dead load per roof foot by spacing, portrait modules on two rails (2.82 ft tributary depth); module-and-racking 2.87 psf from the worked example below, upper bound 3.31 psf
Foot spacingTributary areaDead load at 2.87 psfDead load at 3.31 psfAgainst a 50 lb cap
24 in5.6 sq ft16 lb19 lbWell under
48 in11.3 sq ft32 lb37 lbUnder
72 in16.9 sq ft49 lb56 lbNear or over

At 48 inches the feet carry 32 to 37 pounds each and the cap is comfortable. Stretch the spacing to 72 inches, which some rail spans allow on paper, and the upper-bound case breaks 50 pounds even though the array's average weight has not moved. That is the pattern Washington's fifth condition is written to catch, and it is why a reviewer looks at the attachment plan, not only the weight line.

A quick floor for any array: divide its total weight by 50 to get the fewest roof feet that could keep every foot under the cap with perfectly even sharing. Real layouts use far more, because rail runs need a foot near each end and spacing is set by wind and snow as well as dead load.

Nineteen 430 watt panels on a 1990s truss roof, weighed and spread

Inputs, all stated: nineteen Silfab SIL-430 QD modules (8.17 kW DC) in portrait, a row of 10 and a row of 9, on two rails per row, feet at 48 inches, on a roof of pre-engineered trusses at 24 inches on center with one layer of composition shingle. The ground snow load is taken as 30 pounds per square foot for illustration, below both state ceilings and below Oregon's 36 pound line for wider spacing.

Weight: 19 times 46.3 pounds is 880 pounds of modules over 19 times 20.99, or 398.8 square feet. Racking at the DOE model's 0.66 pounds per square foot adds 264 pounds. Module and racking together weigh 1,144 pounds, which is 2.87 pounds per square foot. Putting every electrical kilogram of the DOE model on the roof as well adds 175 pounds, for 1,319 pounds and 3.31 pounds per square foot.

Feet: the row of 10 runs 37.2 feet (10 times 44.6 inches), so a foot every 4 feet plus one at the end gives 11 feet per rail, 22 for the row. The row of 9 runs 33.5 feet and gets 10 per rail, 20 for the row. That is 42 roof feet. With perfectly even sharing, each carries 1,144 divided by 42, or 27 pounds, and 31 pounds on the upper-bound weight. The tributary-area method gives 32 to 37 pounds for an interior foot, which is the figure that matters, because end feet carry less.

Verdict against the tests: 2.87 and 3.31 are both under Washington's 4 and Oregon's 4.5; 37 pounds is under the 50 pound point cap; trusses at 24 inches and one shingle layer pass Oregon's framing and roofing lines; 30 pounds of ground snow passes both ceilings and allows Oregon's 48 inch spacing if no foot sits within 3 feet of an edge, hip, eave or ridge and the wind lines hold. In either state this roof would likely qualify for the no-engineering path. In Charleston County it would still go to an engineer, because the form requires that on every job.

Price line: 8,170 watts at the $2.95 benchmark is $24,102 in 2024 dollars, before any structural work, which the benchmark excludes. No federal tax credit enters that figure.

Snow on glass: the load that sizes most roofs

Put the dead-load table beside a snow figure and the scale changes. If the design snow load on a roof plane is 20 pounds per square foot, an illustration input rather than a value for any address, the same 48 inch roof foot that carries 32 pounds of array also carries 226 pounds of snow. At 40 pounds per square foot of snow it carries 452. The array is roughly one-eighth of the downward load on that foot in the first case and about one-fifteenth in the second.

This is why both state tests put a ground snow ceiling ahead of the weight test, and why Oregon tightens the spacing of framing attachments above 36 pounds per square foot of ground snow. Ground snow load is a mapped design value, not a measurement of what fell last winter. Engineers and plan reviewers convert it into a roof load with rules that account for slope, exposure and roof temperature, which this guide does not attempt.

Where to find your number: the ASCE Hazard Tool returns design snow and wind values by address under the ASCE 7 standard, and the building department's own design criteria table governs the permit. Ask the department which value its reviewers use, because a county can set its own figures, and the code's load case points to that table by name on the Charleston form.

Snow also behaves differently on glass. Panels are smooth and often slide snow onto a lower roof or a walkway, and the gap under the array changes how snow drifts against it. Those effects are part of an engineer's check where the snow load is high, and they are a practical reason to ask where sliding snow will land before signing a layout.

A 5,400 pascal panel rating is not a roof rating

Datasheets print a mechanical load rating, and it is easy to read as proof the roof is fine. The Silfab sheet lists 5,400 pascals front load and 4,000 pascals rear load, which it converts to 112.8 and 83.5 pounds per square foot. The Qcells page lists a wind and snow load of 3,600 and 8,100 pascals, or about 75 and 169 pounds per square foot.

Those numbers describe how much pressure the glass and frame withstand when mounted the way the manufacturer's installation manual specifies, and the Silfab sheet tells installers to read that manual for mounting specifications. They say nothing about the rafters, the screws into them, or the snow the roof was designed for. A 169 pound module rating on a roof designed for far less snow means the panel will survive a load the framing was never meant to carry. The structural check stays a check of the framing.

When a stamped structural letter is the expected answer

Under the Washington and Oregon tests, an engineer's letter becomes the normal route the moment any line fails. Collecting those lines from both documents gives a practical list of triggers: ground snow load above 70 pounds per square foot; a system heavier than 4 or 4.5 pounds per square foot; modules raised more than 18 inches; framing more than 24 inches on center or not conventional light framing; more than two layers of composition shingle in Oregon; and roof feet spaced so that any one carries more than 50 pounds in Washington.

Charleston County's form sets a different baseline. Above the signature line it says that by signing, the applicant ensures the structure has been reviewed and approved by a licensed engineer to accept the submitted design, and that panels have been designed to withstand wind loads and seismic activity. There is no lighter path written on that form, so the engineer review is part of every residential solar permit there, whatever the array weighs.

Between those poles sit most jurisdictions, and the only reliable way to learn which applies is the building department's solar checklist or the permit technician. The solar permit cost guide covers what those reviews charge. Ask two questions: does the department accept a prescriptive or deemed-adequate path for residential rooftop solar, and if so, which edition and section does it cite? The answer tells you whether the structural line on a quote is a formality or a separate engineering deliverable.

Physical warning signs override any checklist. A sagging ridge line, rafters that were cut or notched for ductwork or skylights, framing that was altered when an attic was finished, water-stained or soft sheathing, or a past fire or termite repair all point to engineering regardless of the weight math. Those are conditions a prescriptive path assumes away, and a reviewer who sees them on the site photos will ask for a letter anyway.

Attic and paperwork to gather before the site survey

  • Framing type (trusses or rafters), member depth and spacing, with a tape-measure photo.
  • Number of shingle layers, from the roof edge or a past roofing invoice.
  • Any cut, notched, cracked or sistered framing, and any attic conversion work.
  • Water stains or soft sheathing under the planned array area.
  • The building department's solar checklist and the code edition it cites.
  • Your ground snow load from the department's design criteria or the ASCE Hazard Tool.
  • Datasheets for the quoted module and racking, so you can redo the weight math.
  • The structural sheet from the plan set: total weight, psf, foot spacing, wind and snow inputs.

Where structural work lands in the price

The DOE benchmark is $2.95 per watt DC for an 8 kW residential system in 2024 dollars, or $23,600, and it is the comparison line this site uses for pricing a quote per watt. Its model lists the residential case as excluding electrical service upgrades and roof repair. Structural reinforcement of the framing is a roof repair in that sense: it is not part of what the $2.95 line describes.

The model does carry the routine part of the roof question. Its fieldwork line for structural balance of system includes the roof assessment along with racking and module mounting, at 0.3 hours per square meter of module, and a separate fixed site-assessment line of $1,067. A quote close to the benchmark therefore already pays for someone to look at the framing; it does not pay for sistering rafters or adding blocking beyond what the mounting design calls for.

When reinforcement is needed, it usually arrives as an adder or a change order after the site survey. The guide to solar quote adders and change orders covers how to get that work priced as its own line before the contract is final. We found no primary source for the national cost of an engineer's letter or of rafter sistering, so this guide prints none; your quote is the only real number.

Reading the structural pages of a permit set

A permit-grade solar plan set normally includes an attachment detail and a structural note or calculation sheet. The useful lines to find are the module make and model, the racking product, the total system weight and its weight per square foot, the roof foot spacing in each zone, the framing size and spacing assumed, the design wind speed and exposure, and the ground snow load used. If any of those is missing, the design was not checked against them. The same set draws the array inside the fire setbacks and roof pathways, which is where the module count, and so the total weight, is really settled.

Compare the framing assumption with the attic. A plan that assumes trusses at 24 inches on center on a house with rafters at 24 inches has the right spacing but the wrong member; Oregon's form treats those differently. Measure the spacing between two framing members and the depth of one, take a photo, and compare it with the note.

The installation process guide shows where the plan set is produced, which is often after signing. Ask for the structural sheet before the contract if you can, or make the contract conditional on it. And because the installer license check tells you who is legally responsible for the work, it is worth running before trusting anyone's structural note.

Roof load and solar panels: questions homeowners ask

How much weight do solar panels add to a roof?

About 2.2 pounds per square foot for the panels alone and about 2.9 with rails and roof feet. Two 2026 datasheets divide out to 2.21 and 2.22 pounds per square foot, and the DOE 2025 benchmark model's composite module and racking weigh 14.22 kilograms per square meter, or 2.91 pounds per square foot. A typical 8 kW array weighs roughly 1,100 to 1,300 pounds in total.

Do I need a structural engineer to put solar on my roof?

It depends on where you live and on the roof. Washington deems a roof adequate without engineering when five conditions hold, including 4 pounds per square foot or less and ground snow of 70 or less. Oregon has a prescriptive checklist with similar limits plus framing and roofing tests. Charleston County, South Carolina, requires the applicant to confirm engineer review on every residential solar permit.

Is snow or the panel weight the bigger concern?

Snow, on almost every roof that gets it. With feet 48 inches apart, an interior roof foot carries about 32 pounds of array but 226 pounds of snow if the roof snow load is 20 pounds per square foot. That is why both state tests cap ground snow load first and why Oregon tightens framing-attachment spacing above 36 pounds per square foot of ground snow.

Can a roof with two layers of shingles hold solar panels?

Under Oregon's prescriptive checklist, up to two layers of composition shingle pass the roofing line; three do not. Washington's exception does not mention shingle layers. Either way, a roof that is near the end of its life is usually worth replacing before the panels go on, since removing and reinstalling an array later costs money.

Where do I find the snow load for my house?

The building department's design criteria table governs the permit, and the ASCE Hazard Tool returns ASCE 7 design values by address. Ask the department which figure its plan reviewers apply, because a county can publish its own values.

Does the panel's 5,400 pascal load rating mean my roof is strong enough?

No. That rating is the module's own mechanical test, 112.8 pounds per square foot front load on the Silfab sheet. It describes the glass and frame when mounted per the manual, not the rafters, the screws into them, or the roof's design snow load.

The roof question has a numeric core and a local wrapper. The numeric core is small and checkable: about 2.9 pounds per square foot for panels and racking, under 40 pounds on each roof foot at ordinary spacing. The wrapper is which authority you build under and what it accepts as proof, and that ranges from a five-line exception in Washington to an engineer's signature on every Charleston County permit.

If your roof clears the weight math but sits in heavy snow country, has altered framing, or is near the end of its covering, those are the conditions worth spending engineering money on. If the roof is the obstacle rather than the array, a ground mount comparison is the next calculation to run, and the roof and property hub collects the other roof-specific questions.

Sources and verification

  • Washington State Legislature, WAC 51-51-03240, Section R324 Solar energy systems (state amendment to the 2021 International Residential Code): Official text. R324.4: rooftop-mounted photovoltaic panel systems installed on or above the roof covering shall be designed and installed in accordance with Section R907. Exception: roof structure deemed adequate when (1) designed for local wind speed and installed per manufacturer, (2) ground snow load not over 70 psf (3.35 kPa), (3) total dead load of modules, supports, mountings, raceways and appurtenances no more than 4 psf (19.5 kg/m2), (4) modules no higher than 18 in (457 mm) above the roofing, (5) no point load over 50 lb (22.7 kg). History: WSR 23-23-104, effective March 16, 2024. The chapter adopts the 2021 IRC with amendments. Checked October 31, 2026.
  • Charleston County Building Inspection Services, Residential Solar Panel Installation form: County reproduction of R324.4.1.1 Roof load (uncovered portions designed per R301.4 and R301.6; covered portions for dead load including panels plus snow load per Table R301.2(1), and dead load excluding panels plus roof live load or snow load, whichever is greater, per R301.6) and R324.4.1.2 Wind load (component and cladding loads per Table R301.2(2), adjusted per Table R301.2(3)). Applicant signs that the structure has been reviewed and approved by a licensed engineer. The form does not name the code edition. Checked October 31, 2026.
  • Oregon Building Codes Division, Prescriptive Rooftop-Mounted Solar Photovoltaic Installation Checklist, Residential, form 440-5952 (5/24), as posted by the City of Happy Valley: Structural criteria under the Oregon Residential Specialty Code: ground snow load 70 psf or less; Wind Exposure B or C; conventional light frame; trusses or rafters 24 in o.c. or less (rafters also per R324.4.1 Exception 1.4 to 1.6); metal, single-layer wood shingles or shakes, or no more than two layers of composition shingle; total PV weight including racking 4.5 psf or less; module top 18 in or less above roof; attachment method 1 (framing or blocking, 24 in, or up to 48 in where ground snow 36 psf or less, not within 3 ft of edge, hip, eave or ridge, wind 120 mph or less in B or 110 mph or less in C) or method 2 (standing seam clamps, 115 lb uplift at 48 in or more, 75 lb below, 24 to 60 in spacing, 10 sq ft product limit, 26 gauge steel, panels 18 in or narrower, #10 screws at 24 in, 1/2 in sheathing). Manufactured dwellings excluded. Checked October 31, 2026.
  • Silfab Solar, SIL-430 QD datasheet (revision 20260804): Module weight 21 kg (46.3 lb); 1,721 x 1,133 x 35 mm (67.8 x 44.6 x 1.37 in); 430 W, 22.1 percent efficiency; maximum surface load 5,400 Pa front, 4,000 Pa rear (112.8 and 83.5 lb/ft2); 3.2 mm glass; read the installation manual for mounting specifications. Cited as data only, not a recommendation. Checked October 31, 2026.
  • Qcells, Q.TRON BLK M-G2+ product page: Format including frame 67.8 x 44.6 x 1.18 in; weight 46.7 lb; nominal power 415 to 440 Wp; wind/snow load 3,600/8,100 Pa. Cited as data only, not a recommendation. Checked October 31, 2026.
  • National Laboratory of the Rockies (formerly NREL), 2025Q1 PV System Cost Benchmark Model, residential inputs (RPV 2025Q1): Linked from the DOE benchmark page. Module 1.9 x 1.03 m, 0.204 kW per m2, 10.99 kg per m2 of module; structural BOS (roof mounts, rails, clamps) 3.23 kg per m2 of module; electrical BOS 8.4 kg per kW AC; inverter 3.6 kg per kW AC; inverter load ratio 1.14; twenty 400 W modules; structural fieldwork includes roof assessment at 0.3 hour per m2; site assessment $1,067 fixed; electrical service upgrade and roof repair excluded. Checked October 30, 2026.
  • U.S. Department of Energy, Solar Photovoltaic System Cost Benchmarks (Q1 2025): Table 2, residential 8 kW DC PV-only: modeled market price $2.95 per watt DC (minimum sustainable price $2.78), 2024 dollars; $23,600 for 8 kW. Benchmark costs exclude subsidies. Checked October 30, 2026.
  • American Society of Civil Engineers, ASCE Hazard Tool: Address lookup for ASCE 7 design values including snow and wind. Named as a lookup only; no value from it is printed in this guide. Checked October 31, 2026.

Weights per square foot are computed from two manufacturer documents and the DOE 2025 benchmark model; your array's module, racking and layout may differ, and the plan set's own figures govern. Code language is quoted from three adopting authorities (Washington's official WAC page, Charleston County's permit form and Oregon's checklist as posted by a city); the model International Residential Code text itself was not read, edition numbering varies, and your building department's adopted code and checklist decide. Snow figures in the examples are illustration inputs, not design loads for any address. This is not engineering advice. No federal tax credit appears in any figure.